Visual Endotracheal Intubation
It is visually inserted through the patient’s mouth into the patient’s trachea to serve as a ventilation tube for oxygen delivery. It is suitable for creating temporary artificial respiration channel under visual guidance during clinical resuscitation or general anesthesia. The patient is connected to the anesthetic ventilator through it, forming a complete maintenance of the patient’s respiratory system.
Materials Used
This product is made of sleeve, tracheal tube, stainless steel wire, catheter connector, drug delivery connector, suction connector, gas filling connector (indicating balloon and single valve), camera, LED cold light source and Micro USB2.0 connector.
Working Principle
It can be inserted into your air tube through your interface, and acts as your air tube to deliver air. It is suitable for establishing human working respiratory ventilation under visual guidance during clinical resuscitation or general paralysis. The patient is connected with the anesthesia ventilator through it to form a complete respiratory system to maintain the patient’s life.
Structure
Visible endotracheal intubation is fully used with display, the driving the camera motherboard,and the endotracheal intubation(including the optical image module inside).
Main Machine structure diagram
Usage
a)Before use, check whether the product package is in good condition, if damaged, do not use;
b)According to the general anesthesia operation routine operation steps;
c)Connect the Micro USB connector of endotracheal intubation to the display
d)Open the mouth and insert endotracheal intubation, the monitor can observe the throat;
e)Look at the screen to guide the endotracheal intubation into the trachea;
f)Disconnect the Micro USB connector from the tracheal intubation to the display, and follow the general anesthesia operation routine;
g)Sputum aspiration on the cuff and mucosal administration of the trachea can be carried out when connected with relevant instruments.
Product parameters(mm)
Type | Min Length | Inside Diameter | Outside Diameter | Package |
G-7.0 | 300 | 7.0±0.20 | 11.5±0.20 | 10 piece/box |
G-7.5 | 310 | 7.5±0.20 | 12.0±0.20 | 10 piece/box |
G-8.0 | 320 | 8.0±0.20 | 12.5±0.20 | 10 piece/box |
Applicable Scene
Anesthesia department
Emergency Department
ICU
Respiratory Department
Feature of Product
1.Fully digital visualization
2.Airway management
ICU can aspirate sputum or other liquids in a timely and accurate manner based on airway management for critically ill patients to reduce the occurrence of VAP; the bronchial occluder can be accurately placed during one-lung ventilation.
3.Three stress responses are reduced to one
4.Suitable for tracheal intubation observation and imaging, providing a non-invasive solution for tracheal intubation
5. Reduce the labor intensity of doctors and avoid cross-infection between doctors and patients
Case presentation
Optional Accessories
TECHNOLOGICAL INNOVATION
High-defifinition Visual
Image return is stable, 1 million pixels, can realize the whole airway monitoring.
Can Suck
It can effffectively prevent, control and reduce the occurrence of ventilator-associated pneumonia (VAP).
Reinforced Type
The catheter is embedded with a reinforced spiral steel wire to increase the resistance to compression and bending of the catheter to prevent the catheter from twisting when the patient’s neck is stretched.
Cleaning Drug Delivery
With an integrated drug delivery cleaning system, it can easily solve drug delivery in the airway, and clean the camera lens in situ, quickly and effiffifficiently.
Low-pressure Cuff
It can reduce local pressure on the airway and effffectively reduce the pressure on the tracheal wall.
Adjustable
The design of the shaping guide wire can adjust the curvature and entry angle of the tube body by changing the curvature according to the patient’s throat, so that the tube can be intubated quickly and accurately to reduce airway damage.
Precautions
1.Attention should be paid to the cooperation between this product and the ventilation equipment, and it should not be loosened.
2.The indwelling time of this product depends on clinical needs, generally not more than 72h.
3.This product is sterilized by ethylene oxide, and the sterilization period is two years.
4.This product is limited to one-time use and is destroyed after use.
5.If the inner packaging is damaged, it is strictly forbidden to use it.
6.Please use it under the guidance of a trained and qualified doctor.
Contraindications
1.The thoracic aortic aneurysm compresses the trachea.
2.Severe bleeding tendency (hemophilia, thrombocytopenic purpura, etc.)
3.Unstable cervical spine injury.
4.Part of the trachea transversely.